Technical Support Note
 

Product(s) involve	:	QCD Version 1.0

Third party product(s)	:	Hi-Color SVGA cards

 

Subject

"Application Error, QCD caused a General Protection Fault in module 
XXXXXXXX.DRV at YYYY:ZZZZ"

Description

User may encounter the above-mentioned error message when executing QCD 
version 1.0 with Windows 3.1 display configured to run Hi-color mode (eg. 16K, 
32K, 64K, 16.7M colors).  The module XXXXXXXX.DRV refers to the VGA driver 
and YYYY:ZZZZ represents the location when the fault occurs.

Solution/Action

This problem can be solved by a newer version of QCD (version 1.10), the new 
QCD be located in SB-BBS:

File Name	:	QCD_WU.ZIP
File Size	:	43903 bytes
Location	:	Distributor conference
			Common file area - 1

The unzipped contents should be as follows:

File Name	:	QCD.EXE		CTCCW.DLL
File Size	:	64832 bytes	32336 bytes
Date		:	07-06-93	07-06-93
Time		:	01:10 hrs	02:20 hrs

All distributors and users are advised to download this file and update all ealier 
version of QCD and related DLL accordingly.